A flex-modeling tutorial for storage: Multiple commodities (gas & electricity)

The multi-feed storage tutorial showed that the flex-model can be a list, so that several devices are scheduled together in one call. Those devices all acted on the same commodity (electricity). But many real sites mix commodities — electricity and gas, for instance — each with its own price.

FlexMeasures handles this with two ingredients:

  • a commodity field on each device in the flex-model, and

  • a per-commodity price listing in the flex-context.

In this tutorial we schedule a small hybrid site with one device on each commodity, and read back a cost breakdown that is tracked per commodity. (For a more general introduction to flex modeling, see Describing flexibility. For the single-commodity, multi-device case, see A flex-modeling tutorial for storage: Multiple feeds into shared storage.)

The use case

A site has two flexible-ish devices, each acting on a different commodity:

  • A battery on the electricity commodity: 20 kW power, 100 kWh capacity, 95% charging and discharging efficiency. It starts at 20 kWh and must reach 80 kWh by 23:00.

  • A gas boiler on the gas commodity: it draws a constant 1 kW of gas every hour, modelled as a fixed load (it is not really flexible, but it still incurs a commodity cost we want to account for).

Prices are flat, but different per commodity:

  • Electricity: 100 EUR/MWh (consumption and production)

  • Gas: 50 EUR/MWh

We want the scheduler to optimise the battery against the electricity price, run the boiler at its fixed gas baseline, and report electricity and gas costs separately.

Building the flex model

As in the multi-feed tutorial, the flex-model is a list with one entry per device. What is new here is the commodity field, which tells the scheduler which price signal applies to each device. It defaults to "electricity".

{
    "flex-model": [
        {
            "sensor": 1,
            "commodity": "electricity",
            "state-of-charge": {"sensor": 3},
            "soc-at-start": 20.0,
            "soc-min": 0.0,
            "soc-max": 100.0,
            "soc-targets": [
                {"datetime": "2024-01-01T23:00:00+01:00", "value": 80.0}
            ],
            "power-capacity": "20 kW",
            "charging-efficiency": 0.95,
            "discharging-efficiency": 0.95
        },
        {
            "sensor": 2,
            "commodity": "gas",
            "power-capacity": "30 kW",
            "consumption-capacity": "30 kW",
            "production-capacity": "0 kW",
            "soc-usage": ["1 kW"],
            "soc-min": 0.0,
            "soc-max": 0.0,
            "soc-at-start": 0.0
        }
    ]
}

Here, sensor 1 is the battery’s power sensor, sensor 2 is the boiler’s power sensor, and sensor 3 is the battery’s instantaneous state-of-charge sensor (referenced from the battery entry so the scheduler records its charge level).

A few things to note:

  • The battery is a normal storage device (soc-at-start, soc-min, soc-max, soc-targets), tagged with "commodity": "electricity".

  • The boiler is modelled as a fixed load. With soc-min and soc-max both 0, it can store nothing; soc-usage of 1 kW forces it to consume exactly 1 kW of gas every hour, which the optimiser cannot change. production-capacity of 0 kW means it can never produce gas.

The prices live in the flex-context. For a single commodity you would pass consumption-price and production-price directly. For multiple commodities, you instead provide a commodities list, one entry per commodity:

{
    "flex-context": [
        {
            "commodity": "electricity",
            "consumption-price": "100 EUR/MWh",
            "production-price": "100 EUR/MWh"
        },
        {
            "commodity": "gas",
            "consumption-price": "50 EUR/MWh"
        }
    ]
}

Each device’s costs are then evaluated against the prices of its own commodity: the battery against electricity, the boiler against gas.

Note

All commodities in one scheduling problem must share the same currency (here, EUR). The prices themselves can of course differ, and may be time series or sensors just like any other price in FlexMeasures.

Triggering the schedule

We schedule on the site asset, so that FlexMeasures considers both devices together in a single optimisation.

$ flexmeasures add schedule \
    --asset 1 \
    --start 2024-01-01T00:00+01:00 \
    --duration PT24H \
    --flex-model flex-model-multi-commodity.json \
    --flex-context flex-context-multi-commodity.json
New schedule is stored.

The scheduler returns one schedule per device (stored on sensors 1 and 2) and a single commitment-cost result that breaks the cost down per commodity.

What to expect

The asset chart shows both commodities together, with the battery’s stock level in between:

Asset-level chart of the hybrid site, showing battery power, battery state of charge, and the gas boiler.

Reading the chart top to bottom:

  • Battery power (electricity) charges at its full 20 kW for the first three hours, then makes one partial-power step, which compensates for its charging efficiency losses to land exactly on the 80 kWh target, and then sits idle for the rest of the day. In the final hour it discharges at −20 kW. Because the electricity price is flat, there is no cheaper window to wait for, so it simply charges as early as possible (prefer-charging-sooner is on by default).

  • Battery state of charge makes the effect of that power schedule explicit: the stock rises from the 20 kWh soc-at-start, reaches the 80 kWh target during the morning, holds there through the idle hours, and drops in the final hour as the battery discharges. This is the charge level you would otherwise have to infer from the power curve.

  • Gas boiler (gas) runs at exactly 1 kW every single hour. The soc-usage field makes this a fixed load that the optimiser cannot shift — its only effect on the result is the gas cost it incurs.

The schedules match the cost figures reported by the scheduler:

Electricity (battery)
  Net charge needed : 80 kWh − 20 kWh        = 60 kWh stored
  Grid draw         : 60 kWh ÷ 0.95          = 63.16 kWh
  Charge cost       : 63.16 kWh × 100 EUR/MWh ≈  6.32 EUR
  Discharge credit  : 20 kWh × 100 EUR/MWh   = −2.00 EUR
  Net electricity                            ≈  4.32 EUR

Gas (boiler)
  Consumption       : 1 kW × 24 h            = 24 kWh
  Gas cost          : 0.024 MWh × 50 EUR/MWh =  1.20 EUR

Total                                        =  5.52 EUR

The commitment-cost result keeps these as separate entries — electricity net energy (≈ 4.32 EUR) and gas net energy (1.20 EUR) — so you can always see how much each commodity contributed.

Note

This same pattern extends to more devices and more commodities. Add further entries to the flex-model list (each with its commodity) and a matching entry in the flex-context commodities list. As long as all commodities share one currency, FlexMeasures optimises them together and reports each commodity’s cost on its own.

We hope this demonstration helped to illustrate multi-commodity scheduling. To revisit scheduling several devices that share a single commodity and stock, head back to A flex-modeling tutorial for storage: Multiple feeds into shared storage. Next, in Toy example IV: Computing schedules for processes, we’ll turn to something different: the optimal timing of processes with fixed energy work and duration.